Introduction
There are no valuable laboratory methods for clinically detecting gastric cancer (GC). Nucleic acid aptamers, single-stranded oligonucleotide ligands generated through in vitro selection, can bind to target molecules with high specificity and affinity like antibodies, but they have several advantages over antibodies: synthetically prepared, easily modified, and thermally stable, making aptamers promising for medical diagnostics. In our previous study, we selected a group of aptamers using GC serum as targets. In this study, we used these aptamers to develop fluorescent aptasensors, aiming to provide a novel method for laboratory GC detection.
Aims & Methods
Ten aptamers with rich and diverse secondary structures were selected and synthesized, with Cy3 fluorophores labeled at the 5' end to provide a fluorescence signal and polyethylene glycol 2000 (PEG2000) modified at the 3' end to reduce the adsorption of non-specific serum proteins to the aptamers. The aptamers were incubated with serum samples from patients with GC or benign gastric diseases (BGD), including chronic gastritis, peptic ulcers, and gastric polyps, and the fluorescence intensity (F1) was measured using a full-spectrum microplate reader. Graphene oxide (GO) was then added and incubated to quench the fluorescence of unbound aptamers via its excellent fluorescence resonance energy transfer properties, after which the fluorescence intensity (F2) was measured. The ratio (Fr) of F1 and F2 was calculated, and its diagnostic value for GC was analyzed using receiver operating characteristic (ROC) curves.
Results
After optimizing the experimental conditions, we successfully developed GO-based PEGylated fluorescent aptasensors. The 10 aptasensors were first applied to detect small-sample serum specimens from GC and BGD (n = 32 each), and the maximum area under the ROC curve (AUC) of them for distinguishing GC from BGD was 0.870-0.990. The top five aptasensors in terms of diagnostic performance were selected to be further analyzed in a total of 200 GC cases and 100 BGD cases and exhibited good diagnostic performances for GC, including early-stage GC (EGC, TNM I+II), and the combination of the 5 aptasensors via a logistic model further improved the diagnostic value for GC (Table 1). They outperformed the classic serum tumor markers CEA (AUC=0.694, 95%CI 0.632-0.756), CA19-9 (AUC=0.573, 95%CI 0.507-0.634), and CA72-4 (AUC=0.617, 95%CI 0.401-0.834).
Conclusion
We successfully developed a GO-based PEGylated fluorescent aptasensor capable of effectively and easily detecting GC, with potential for clinical application.
Table 1. The diagnostic performance of 5 aptasensors for the diagnosis of GC
| Aptasensor | GC (n=200) vs. BGD (n=100) | EGC (n=109) vs. BGD (n=100) |
| Fr | AUC (95%CI) | Fr | AUC (95%CI) |
| AP9-9 | 6.32±0.55 vs. 5.49±0.74*** | 0.849 (0.799-0.900) | 6.33±0.56 vs. 5.49±0.74*** | 0.853 (0.799-0.907) |
| AP15-8 | 16.47±4.58 vs. 10.35±3.21*** | 0.850 (0.807-0.893) | 16.39±4.87 vs. 10.35±3.21*** | 0.832 (0.777-0.886) |
| AP15-16 | 14.48±3.32 vs. 9.56±3.13*** | 0.854 (0.810-0.899) | 14.62±3.33 vs. 9.56±3.13*** | 0.862 (0.811-0.912) |
| AP15-25 | 9.45±1.31 vs. 7.74±0.98*** | 0.879 (0.842-0.916) | 9.30±1.26 vs. 7.74±0.98*** | 0.860 (0.811-0.908) |
| AP18-7 | 13.20±1.66 vs. 10.13±2.35*** | 0.856 (0.798-0.914) | 13.22±1.64 vs. 10.13±2.35*** | 0.857 (0.799-0.916) |
| Combination | - | 0.973 (0.953-0.992) | - | 0.970 (0.949-0.992) |
*** P<0.001