Introduction
Atrophic gastritis (AG) is the main precursor of gastric cancer. While expert centers report high diagnostic accuracy for AG using advanced white-light endoscopy (WLE), its real-world performance in high-volume routine outpatient settings remains unclear. The visual diagnosis depends on examiner experience and examination time, increasing the risk of overdiagnosis and underdiagnosis in everyday practice.
Aims & Methods
To compare endoscopic and histological assessment of gastric atrophy in routine practice and evaluate endoscopist performance.
A total of 60 patients were included in the preliminary analysis of an ongoing prospective real-world study, including 48 women (80%) and 12 men (20%). The mean age was 52.45 (range 35–80 years). All underwent routine EGD at a multidisciplinary outpatient clinic. Procedures were performed by 4 endoscopists using standard equipment (Sonoscape HD-500) under routine time constraints. No chromoendoscopy or image-enhanced techniques were used. Targeted biopsies were taken according to the updated Sydney protocol for histological staging (OLGA/OLGIM). Mild atrophy (1+) in the presence of active H.pylori infection was classified as atrophy for the primary analysis, with the understanding that some of these cases may represent reversible pseudoatrophy. These patients were excluded. Histology was assessed by multiple pathologists in routine clinical practice, which may have introduced interobserver variability.
Results
Patients were stratified into 3 groups based on concordance between endoscopic suspicion and histological confirmation of AG. Group A (endoscopy positive / histology positive) comprised 53.3% of patients (n=32), representing true-positive cases. Within this group, correct assessment of the extent of atrophy was observed in 75% (n=24; subgroup 1a), overestimation atrophy in 15.6 % (n=5; subgroup 1b), underestimation of the extent was noted in 9.4% (n=3; subgroup 1c). Group B (endoscopy positive / histology negative) accounted for 36.7% of patients (n=22), corresponding to false-positive cases (overdiagnosis). Group C (endoscopy negative / histology positive) included 10% of patients (n=6), representing false-negative cases (missed diagnoses). The performance of endoscopists in detecting gastric mucosal atrophy was also evaluated (Table 1).
| Endoscopist | Procedures (n) | Exact agreement(%) | Overdiagnosis (FP,%) | Missed atrophy (FN,%) |
| 1 | 16 | 43.8 | 43.8 | 0 |
| 2 | 11 | 27.2 | 36.4 | 36.4 |
| 3 | 23 | 56.5 | 34.8 | 8.7 |
| 4 | 10 | 10.0 | 80 | 0 |
Substantial interobserver variability was observed among endoscopists. Diagnostic accuracy ranged from 10% to 56.5%. Overdiagnosis represented the predominant source of error, reaching up to 80%. In contrast, missed atrophy (false-negative rate) was less frequent overall but showed marked variability, with one endoscopist demonstrating a rate as high as 36.4%. These findings highlight a tendency toward overdiagnosis in routine practice and significant operator-dependent differences in diagnostic performance. Overall, WLE showed a sensitivity of 72.7% and a ppv of 59.3% for the detection of AG in this preliminary cohort. The study is ongoing, and further recruitment, including a control group, is planned.
Conclusion
WLE demonstrated moderate diagnostic accuracy for AG in routine practice, with a predominance of overdiagnosis. These findings highlight strong operator dependence and limitations of WLE under routine conditions, supporting the need for histological confirmation. Further standardization and training may improve diagnostic consistency.