Introduction
Real-time optical diagnosis of colorectal polyps underpins the resect-and-discard strategy, which can reduce pathology costs and streamline colonoscopy workflow. While narrow-band imaging (NBI) differentiates neoplastic from non-neoplastic lesions accurately in expert hands, its real-world performance depends heavily on endoscopist experience. AI-based computer-aided diagnosis (CADx) has been shown to improve diagnostic accuracy, but whether it also shortens the time required for in-vivo characterization remains largely unexplored. We therefore evaluated the impact of NBI-based CADx on time required for diagnosis (diagnostic time) and performance across endoscopists of different experience levels.
Aims & Methods
This was a single-center, prospective multi-reader image-based study. The inclusion criteria were pathologically confirmed colorectal polyps measuring less than 10 mm in diameter and patients aged over 20 years who did not decline the secondary use of their clinical data. The exclusion criteria were polyposis syndromes or inflammatory bowel disease, absence of available NBI images, inadequate image quality, and images depicting more than one lesion. Between July 2021 and January 2022, a total of 2,031 colorectal polyps were resected at our hospital, of which 1,860 polyps were eligible. From these, 100 pathologically confirmed polyps were randomly selected, and one representative NBI image was prepared for each lesion.
The images were independently evaluated by 12 endoscopists (six board-certified experts and six non-experts), who classified each lesion as neoplastic or non-neoplastic. Sessile serrated lesions (SSLs) were considered neoplastic in this study.
In the first session, images were assessed without CADx. After a 4-week interval, a second session was conducted with CADx assistance providing pathological predictions. Diagnostic time per lesion was recorded and compared between the two sessions. Diagnostic time was defined as the interval between image presentation on the computer screen and the entry of the endoscopist’s diagnosis and was automatically recorded by the computer system. The primary endpoint was diagnostic time per lesion. Secondary endpoints included sensitivity, specificity, positive predictive value, negative predictive value, overall accuracy, and the proportion of high-confidence diagnoses. Statistical analyses were performed using the Wilcoxon signed-rank test, Fisher’s exact test, the weighted generalized score test, and McNemar’s test, as appropriate.
The study received ethics approval (no. 2023-118-A) and complied with the Declaration of Helsinki.
Results
Out of the 100 lesions, there were 72 adenomas/intramucosal carcinomas, 6 SSLs, 21 hyperplastic polyps, and 1 juvenile polyp. CADx assistance significantly reduced diagnostic time(mean±SD) from 5.8 ± 4.7 s to 4.7 ± 3.1 s (P < 0.001). This reduction was observed in both non-experts (6.2 ± 4.6 s to 4.9 ± 3.1 s) and experts (5.5 ± 4.9 s to 4.5 ± 3.0 s) (both P < 0.001). Sensitivity improved from 89.0% (95% CI: 86.8-90.9) to 97.0% (95% CI: 95.6-98.0) (P < 0.001), and overall accuracy increased from 86.9% (95% CI: 84.9-88.8) to 93.2% (95% CI: 91.6-94.5) (P < 0.001), whereas specificity remained unchanged (80.1% [95% CI: 74.9-84.6 vs. 80.4% [95% CI: 75.3-84.9, P = 1.0). The high-confidence diagnosis rate increased from 74.0% (95% CI: 71.4-76.5) to 89.0% (95% CI: 87.1-90.7) (P < 0.001).
Conclusion
CADx may improve efficiency in the optical diagnosis of colorectal lesions.