Introduction
We describe a deployment complication of the Over-The-Scope Clip (OTSC) during haemostasis of a duodenal ulcer, and thread transection modalities.
A 74-year-old male was admitted for an intracranial haemorrhage and this was complicated with upper GI bleeding. There was a drop in the haemoglobin, with raised urea. An oesophagogastroduodenoscopy (OGD) revealed a Forrest 1B ulcer in the anterior wall of the first part of the duodenum.
Aims & Methods
Endoscopic haemostasis with thermacoagulation, injectable epinephrine, and four through-the-scope (TTS) clips were deployed. However, the patient had recurrence of melena three days later with a further drop of the haemoglobin. Repeat OGD showed the duodenal ulcer with active oozing of blood, and the previous TTS clips had been dislodged. Next line therapy with OTSC was applied with satisfactory capture at the stigmata site. However, the thread attached to the clip was not released and was clasped within the clip jaws at the ulcer site.
Results
Mechanical cutting with an Endo Loop cutter was unsuccessful, and further attempts with Argon Plasma Coagulation to thermally severe the thread were partially successful but with incomplete transection of the thread. Due to the prolonged procedure, the patient developed fast atrial fibrillation, and further attempts were aborted and to be done the next day. The thread remained intact from the OTSC in the duodenum, protruding out of the patient’s mouth and secured for the subsequent attempt.
The final attempt was done with a hot snare. A Rat Tooth forcep was first used to grasp the thread and brought through the scope channel and out of the opening. A snare was then passed down the thread and railroad into the stomach. It was tightened around the thread and cut current was used to transect the string successfully and removed from the patient’s mouth. Careful consideration was done to transect the thread as near to the OTSC as possible and to avoid injury to the stomach and duodenal mucosa. The OTSC remained intact and no rebleeding was observed from the duodenal ulcer indicating successful haemostasis.
The complication is likely due to the presence of excess thread from the OTSC cap, which was likely suctioned into the closure of the clip jaws along with the duodenal mucosa. Due to the closure of the OTSC, the protruding segment of thread entrapped within the cap cannot escape, remaining tethered to the clip jaws. Though it presents no immediate risk to the patient, the retention of the thread within the intestinal lumen is not ideal and warrants removal.
Conclusion
This video case demonstrates several transection modalities for an entrapped OTSC thread. The hot snare with cut current mode has the highest transection efficacy for this deployment complication.
References
(1) Debas H T, Carvajal SH. (1994). Vagal regulation of acid secretion and gastrin release. Yale Journal of Biology and Medicine, 67(3-4), 145-151.
(2) Quinones GAO, Woolf A. (2023). Duodenal Ulcer. National Center for Biotechnology Information.
(3) Galloro G et al. (2022). Endoscopic clipping in non-variceal upper gastrointestinal bleeding treatment. Clinical Endoscopy, 55(3), 339-346
(4) Koh JH et al. (2025) Over-the-Scope Clip Versus Standard Endoscopic Treatment in Patients With Acute Nonvariceal Upper Gastrointestinal Bleeding: A Systematic Review and Meta-Analysis. Journal of Gastroenterology and Hepatology, 40(10), 2373-2390
(5) Abbas D et al. (2023). Analysis of Reported Adverse Events Related to Over-the-Scope Clips: A MAUDE Database Analysis. Techniques and Innovations in Gastrointestinal Endoscopy, 25(2), 106-112.
(6) Tashimi T, Nonaka K, Ryozawa S. Unprecedented problems and troubleshooting during over-the-scope clip system use: Suction error and suture cutting procedure. Digestive Endoscopy, 31(2), 36-37.
(7) Zenker M. (2008). Argon plasma coagulation. GMS Krankenhhyg Interdiszip, 3(1). PMID: 20204117.
(8) Ishida T et al. Efficacy of forced coagulation with low high-frequency power setting during endoscopic submucosal dissection. World Journal of Gastroenterology, 23(29): 5422-5430.