Introduction
Capsule Endoscopy (CE) is a minimally invasive modality central to the evaluation of small bowel inflammatory disorders, particularly Crohn’s disease. Accurate identification of ulcers and erosions is essential for disease activity assessment, therapeutic decision-making, and monitoring response. However, manual CE review is time-consuming and subject to interobserver variability. Advances in artificial intelligence (AI), particularly convolutional neural networks (CNNs), offer the potential to enhance diagnostic performance, reduce variability, and improve workflow efficiency.
Aims & Methods
To develop and validate a robust AI model for the detection of small bowel ulcers and erosions across multiple CE systems and international centers. A prospective, multicenter study (January 2021–September 2025) was conducted across thirteen centers in Portugal, Spain, Brazil, Uruguay, Australia, Mexico, Latvia, Saudi Arabia, and the United States. A total of 505 complete CE studies were included. AI-generated reports were reviewed by an expert and compared with standard-of-care (SoC) interpretations. An expert consensus panel established the reference standard. Diagnostic performance was assessed using sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy, and area under the receiver operating characteristic curve (AUC-ROC). Reading time was recorded for AI-assisted interpretation.
Results
Expert consensus identified ulcers and erosions in 152 patients (30.0%) compared to 121 on the SoC arm (23.9%).
Compared with the reference standard Soc achieved a sensitivity of 71.2%, specificity of 94.0%, PPV of 85.8% and NPV of 86.5% while the AI-assisted reading achieved a sensitivity of 89.4%, specificity of 85.1%, PPV of 75.2% and NPV of 94.1%
AI achieved a significantly higher sensitivity (+18.2%), indicating improved detection of inflammatory lesions, although this was accompanied by a reduction in specificity (−8.9%). PPV was lower with AI, reflecting an increased number of false positives, while NPV was substantially higher, supporting strong reliability in excluding disease.
AUC-ROC was higher for AI (0.872 vs 0.826), indicating superior overall discriminative performance. Performance remained consistent across devices and centers. Mean AI-assisted reading time was 335 seconds per examination.
Conclusion
AI-assisted CE significantly improves the detection of small bowel ulcers and erosions, with a marked increase in sensitivity compared to conventional reading. This enhanced detection comes at the cost of reduced specificity, reflecting a shift toward a more sensitive, less conservative diagnostic profile.
Importantly, the higher AUC-ROC and NPV indicate improved overall diagnostic performance and stronger ability to exclude disease, which is clinically relevant in inflammatory bowel disease assessment. The multicenter, multidevice design supports the robustness and generalizability of the model.
These findings position AI as a valuable adjunct in CE interpretation, particularly for minimizing missed inflammatory lesions and improving workflow efficiency, supporting its integration into routine clinical practice.
References
.
Disclosure
No disclosures