Introduction
Benign anal canal conditions are common, clinically impactful, and frequently associated with proctological symptoms and functional impairment, creating a substantial burden for patients. Precise diagnostic assessment is essential to guide appropriate therapeutic planning and ensure optimal outcomes. Endoanal ultrasonography (EAUS) remains the reference modality for evaluating the sphincteric complex, yet its operator dependency, steep learning curve, and variability in image interpretation continue to limit consistency and reduce interobserver agreement. Artificial intelligence (AI) offers a compelling opportunity to address these constraints by enhancing image interpretation, reducing reliance on individual expertise, and strengthening diagnostic standardization. This study aims to validate an AI model capable of automatically detecting and characterizing benign anal lesions in EAUS exams, reinforcing the need for more consistent, scalable, and clinically dependable evaluation in anal disorders.
Aims & Methods
A bicentric retrospective study evaluated 13 787 EUAS radial-probe exams between April 2022 and January 2024. A total of 13787 frames were classified into fissures (632), external lacerations (1989), and internal lacerations (1687), intersphincteric fistula (5163), transsphincteric fistula (3581) and internal atrophy (735), after expert review. The dataset was divided into 90% for training and 10% for testing. Performance metrics included sensitivity, specificity, and accuracy.
Results
For external lacerations, the CNN achieved 94.1% sensitivity, 99.6% specificity and 98.9% accuracy. For internal lacerations, achieved 95.0% sensitivity, 98.4% specificity and 98.4% accuracy. In the case of anal fissures, achieved 98.4% sensitivity, 98.6% specificity and 98.7% accuracy. Regarding inter and transsphincteric fistulas, sensitivity was 92.5% and 96.9%, specificity was 99.5% and 97.8%, and accuracy was 97.0% and 97.4%, respectively. For internal atrophy, sensitivity was 97.5%, specificity was 99.9% and accuracy was 99.9%.
Conclusion
Our findings demonstrate that AI can reliably support the detection and characterization of benign lesions on EAUS and highlight its capacity to improve diagnostic consistency in this setting. In addition to enhancing accuracy and reducing operator dependency, AI may drive meaningful standardization and function as a valuable educational tool for clinicians in training. By guiding interpretation and emphasizing key anatomical structures, it has the potential to shorten the demanding learning curve associated with EAUS. Although these results are encouraging, they represent an early milestone in a wider developmental pathway. Future work will focus on integrating three dimensional network reconstruction to deliver richer anatomical insight and further elevate diagnostic precision.
Disclosure